Making a little energi go a long way

Heat Interface Unit

Tried. Tested. Trusted Teknologi.

Danfoss FlatStation Heat Interface Units are suitable for small one bedroom apartments up to major commercial applications. Please contact us for design, sizing and selection.

Why choose Danfoss Flatstations

Key features and benefits

Quality

Built to last. Danfoss FlatStations go through comprehensive quality assurance and are built to standards that adhere to ISO/TS 16949:2009

Performance

The most important design objective for a 4G Heat Network (HN) is to consistently achieve low return temperatures under all operating

Easy to use

Built to last with top-notch craftsmanship, high-quality components and Scandinavian heat pump know-how.

Key data for the HIU product range

Heat Interface Unit product range

NOVI

Capacity
32-57kW
Maximum Supply Temperature
99°C
Maximum Nominal Pressure
16 bar
Maximum Differential Pressure
6 bar
Minimum CW Pressure
1 bar
Required Differential Pressure
50kPa
Keep Warm Temperature
~8°C Below DHW Set Point
Flow Control
IHPT
Plate Material
Stainless Steel
Heat Exchanger Brazing Material
Copper
Meter Pre-fit Option
Yes
Required Approach Temperature
5°C
Electrical Supply
None
Connection Sizes
G ¾” (int. thread)
Pipe Dimensions
Ø 18 mm
Dry Weight Incl. Enclosure
7-9kg
Fully Insulated Enclosure
EPP
Insulated Cover Thermal Conductivity
0.038-0.040Wm-2K-
Pipe Configuration
Bottom Fed

FlatStation Capacity Examples

DHW PHEX Size Heat Network Supply [°C] CW/DHW [°C] DHW Capacity [kW] DHW Flow Rate [l/min] Heat Network Return [°C] Pressure Loss [kPa]
UNKNOWN UNKNOWN UNKNOWN 32-57 UNKNOWN UNKNOWN UNKNOWN

Downloads

Key Features

Danfoss FlatStation Heat Interface Units

Danfoss FlatStation Heat Interface Units

A partner through the full project lifecycle

Our approach is built around practical and technical support, clear advice and long-term partnership, not just about supplying products.

Heat pumps IN HYBRID ENERGY CENTRE

In a hybrid energy centre, heat pumps are sized to provide the maximum share of energy (kWh) but are not sized to the peak building load (kW) as this is extremely expensive and results in over-sized, under utilised appliances. Hence, cost effective peak capacity should be provided by boilers.

Information about our product

Frequently asked questions

What are the key features and benefits of DELTA electric boilers?+

The key features and benefits of DELTA electric boilers include:
- Low carbon heat source: Electric boilers provide a low carbon heat source, making them ideal for 'all-electric' buildings where there is no gas connection.
- Consistent, stable flow temperature: DELTA electric boilers provide flow temperatures up to 95°C as standard, ensuring a consistent and stable heat output.
- Optimised, modulating output: The boilers use multiple elements to modulate the output from maximum down to a single stage of operation, matching the site's heating demand.
- Integration with other heat sources: DELTA electric boilers can be integrated with other heat sources, such as heat pumps, to form hybrid energy centres.
- Flexibility for new build and retrofit: DELTA electric boilers are suitable for both new build and retrofit installations into existing buildings.

How do DELTA electric boilers support heat pumps in hybrid energy centres?+

DELTA electric boilers provide peak capacity and system resilience to support heat pumps in hybrid energy centres. This minimises the capital cost of the heat pump installation and reduces the external footprint required for an air source heat pump. By providing the peak capacity, the heat pump can be sized more optimally, reducing both the CAPEX and OPEX costs.

What are the key statistics of DELTA electric boilers?+

Key statistics of DELTA electric boilers include:
- Available in 25 models ranging from 31 to 1400 kW
- Large turn-down ratio, modulating down to a single stage of operation
- Minimises CAPEX as heat pumps do not need to be sized to peak capacity
- Overcomes heat pump capacity and flow temperature shortfall
- Adds system resilience with flow temperatures up to 95°C as standard
- Available in 400V 3-phase, with 690V also available on some models
- Packaged plate heat exchanger (PHE) option for network pressures over 6 bar

How can DELTA electric boilers be used to balance the electricity grid?+

DELTA electric boilers can be used to balance the electricity grid by reacting to tariff and carbon signals and quickly turning surplus low-cost renewable power generation into stored hot water. This helps to stabilise the grid and make the most efficient use of available renewable energy sources.

What are the considerations for the use of DELTA electric boilers in all-electric energy centres?+

In an all-electric energy centre, DELTA electric boilers provide cost-effective peak capacity to support an optimised heat pump installation. The electric boilers' ability to turn down to a single stage of operation and modulate in small increments allows them to top-up the output from the heat pumps as required. Boiler capacity can be large, but its share of the overall energy use should be minimised to maintain a low carbon footprint and low operating costs. Additionally, as the electric boiler operation is designed to be intermittent or as a standby plant, long-term safety and reliability are important considerations.

Heat and Power documents

Relevant links and downloads

Datasheets

Access product datasheets with key technical information, performance data and requirements for our Heat and Power solutions.

Specifications

Browse detailed product specifications to support system design, project planning and technical compliance across a range of applications.

Design Guides

Explore practical design guidance, best practices and expert advice to deliver efficient and effective Heat and Power systems.

Technical Guides

In-depth technical resources covering commissioning, operation and maintenance to support every stage of your project.

Have a question?

Please contact us. If you would like
to talk to us directly, please call or
send us an inquiry

Search

To search for documents, please visit Downloads and use the search function / filters on that page.

    [gatormailsmartform id="414"]

    If you are unsure or would like to speak to us directly, please contact +44 (0) 1483 771910

    Submit Your Enquiry

    Provide us with the relevant information in the form and our team will reach out to you