FloCon modular solutions centralises the control, commissioning, and pre-commission cleaning of terminal branches. This significantly reduces time taken to install, flush and balance the HVAC system. FloCon modules provide a single access point for up to 7 terminal units and ensures security that every terminal will receive the flow conditions necessary for its optimal operation.
In this table you will see all the relevant key data for the FloCon product range:
![]() | ![]() | |
|---|---|---|
| Category | DPCV Module | PICV Module |
| Type | Differential pressure control valve | Pressure independent control valve |
SAV started developing Commissioning Modules in 1999 and fully introduced them to the market in 2001, holding a patent for the design. Since then, SAV has been at the forefront in developing well-designed HVAC solutions that contribute to energy savings, simplification of commissioning and optimised performance whilst delivering best user comfort.
Figures are compared to traditionally designed rigid fan coil systems, you can download the report here: Cost & Time savings using FloCon
faster installation
faster balancing of terminal units
faster flushing of horizontal mains pipework
faster installation & flushing of terminal units
Modern buildings seldom retain a fixed usage pattern throughout their lifespan, hence, building services systems need to be as flexible as possible to facilitate these changes. FloCons modular approach allows terminal units to be added, moved, or removed without draining or involving disruptive rigid pipework alterations.
Haka multilayer PEX pipework is stronger, more efficient (less heat loss and pressure drop) and is better for the health of the system as it eliminates oxygen diffusion which leads to corrosion of components.


Where a HVAC system might be shared by multiple consumers, installing an MID approved ultrasonic meter within each FloCon module provides the necessary granularity of energy consumption for accurate targeted billing. Any unexplained increases in energy consumption can be quickly identified and investigated.
In addition, ongoing accurate delta T and flow rate measurement facilitates troubleshooting, by quickly highlighting outlying low delta T and blockages.
Have a question?
If you would like to talk to us directly, please call or send us an inquiry!
The FloCon Commissioning Module is a modular solution that centralises the control, commissioning, and pre-commission cleaning of terminal branches. It significantly reduces the time taken to install, flush, and balance the HVAC system by providing a single access point for up to 7 terminal units and ensuring that each terminal receives the necessary flow conditions for optimal operation.
The key features and benefits of the FloCon Commissioning Module include:
- 28% faster installation
- 56% faster balancing of terminal units
- 57% faster flushing of horizontal mains pipework
- 77% faster installation & flushing of terminal units
- Modular approach that allows terminal units to be added, moved, or removed without draining or involving disruptive rigid pipework alterations
- Use of Haka multilayer PEX pipework that is stronger, more efficient, and better for the health of the system by eliminating oxygen diffusion
- Inclusion of an MID approved ultrasonic meter within each module for accurate targeted billing and energy consumption monitoring
Modern buildings often have a changing usage pattern throughout their lifespan, so building services systems need to be as flexible as possible to accommodate these changes. The FloCon Commissioning Module's modular approach allows terminal units to be added, moved, or removed without the need for draining or disruptive rigid pipework alterations. This flexibility ensures that the HVAC system can adapt to the evolving requirements of the building and its occupants.
Where an HVAC system is shared by multiple consumers, the FloCon Commissioning Module includes an MID approved ultrasonic meter within each module. This provides the necessary granularity of energy consumption data for accurate targeted billing. Additionally, the ongoing accurate measurement of delta T and flow rate facilitates troubleshooting by quickly highlighting any outlying low delta T and blockages, allowing for prompt investigation and resolution.
SAV started developing Commissioning Modules in 1999 and fully introduced them to the market in 2001, holding a patent for the design. Since then, SAV has been at the forefront in developing well-designed HVAC solutions that contribute to energy savings, simplification of commissioning, and optimised performance while delivering the best user comfort. The FloCon Commissioning Module is the result of SAV's ongoing commitment to innovation and providing practical solutions for the HVAC industry.
We use strictly necessary cookies for the website to function and cannot be switched off in our systems. Analytics cookies help us understand how our site is used, and targeting cookies make our content and advertising more relevant to you. You can accept all cookies or manage your preferences. For more information about the cookies we use, see our Cookies Policy.
To search for documents, please visit Downloads and use the search function / filters on that page.
Provide us with the relevant information in the form and our team will reach out to you